What was found
MAIN DECK FLOOR SUPPORT STA 680-740 AND RBL 65 HAS SEVERAL AREAS OF CORROSION REMOVED CORRISION INBD CHORD STA 680-740, RBL 65 IAW SRM 53-30-13. MAT THICKNESS .190", MAT REMOVED .100", MAT REMAINING .090". FOUND OUT OF LIMITS IAW SRM 53-30-13, PG 102, FIG 101. REMOVED AND REPLACE INBD CHORD ( PN 143N8328-54 BATCH NUMBER 1693914 "ON") FROM STA 680-740 AND RBL 65, WL 208 IAW SRM 51-40-02.