What was found
RT WING INBD FLAP UPPER SURFACE AT L/E AREA FOUND DENTED AT APPROX X1FH 183.300 AS MARKED. RT WING INBD FLAP UPPER SURFACE AT L/E APPROX XIFH183.300, DENTED AREA MEASURED, DEPTH = 0.065", LENGTH = 1.5" FOUND WITHIN LIMIT IAW SRM 57-00-00 FIG. 206 REV. 41, HFEC INSP CARRIED OUT IAW DAC NDT SPM REV 13 PART 06-10-01.001 ON DENT AREA AND FOUND NO CRACK EVIDENT. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100 REV 108.