What was found
RT WING OTBD FLAP OTBD HINGE (WING MOUNTED) ACTUATOR ATTACHMENT INBD LUG, HOLE FOUND CORROSION. RT OTBD FLAP FWD OTBD ACTUATOR INBD HOLE REWORKED AND FOUND EXCEED LIMIT IAW CMM 57-44-09 REV65. REPAIR FOUND TO BE ACCEPTED IAW EA 1-5750-76656 IAW EA 1-5750-76656. BUSHING FABRICATED AND INSTALLED IAW CMM 57-44-09 REV 65. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100 REV 108. REWORK REQUIRED (JPF ITEM NR12) FINAL BORE DIMENSION IS NOT ACCEPTABLE IAW EA 1-5750-76656.