What was found
MAIN DECK STA 800 L/BL8 (APPROX) AFTER REMOVAL OF TV MONITOR DOUBLERS FOUND WITH DOUBLE DRILLED HOLES. CUT OUT DAMAGED FRAME AT STA 800 STR 5L TO 5R IAW SRM 53-00-07 FIG 2014 R1,REMOVED 2 EA. ACFT BRACKET 1 EA LAV BRACKET 1 EA ELEV BRACKET FOR FOM IAW SRM 51-40-02, FABRICATED FRAME ON MAE TRAVELER NR T9/809365, FABRICATED CHANNEL NR1 ON TRAVELER NR T9/809366 AND CHANNEL NR 2 ON NR T9/809367, LOCATED AND DRILLED HOLES ON FRAME AND ALL REPAIR PARTS IAW SRM 51-40-05, TREATED AND PRIMED IAW SRM 51-20-01, AND INSTALLED ALL REPAIR PARTS REMOVED IAW SRM 51-40-02 AND 53-00-07 FIG 210 REPAIR 1. THIS IS AN "A" REPAIR. MAJOR REPAIR.