What was found
MAIN DECK UPPER SIDEWALL FRAME AT LT STA 1621, 13L FOUND DENTED. MAIN DECK DENTED FRAME AT LT STA 1621 13L REPAIRED IAW SRM 53-00-07 FIG. 201. REPAIR 2 REV 42. REPETITIVE INSP REQUIRED, INITIAL AT 14,500 CYCLES AND REPETITIVE INSP AT 9.500 CYCLES TO BE CARRIED OUT IAW SRM 53-00-07 FIG 201 REPAIR 2, REV 42. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100 REV 108.