DURING T/O POWER APPLICATION, WHEN TOGA PWR WAS SELECTED THE GREEN A/THR LIGHT ILLUMINATED HOWEVER THE THROTTLES WOULD NOT MOVE. ACCOMPLISHED RTO AT 25 KTS. VERIFIED AT BLOCK IN NR1 ENGINE ANTI ICE WAS FAULTING IN ECAM. RELEASED FOR SERVICE IAW MEL: 22-30-01-A CATEGORY: C EXPIRATION: 30NOV09 "MEL 22-30-01-A: ATS - INOP, ALL THRUST SETTINGS MUST BE MANUALLY SET. NO OPS WITHIN METRIC AIRSPACE. A/C CATII" CHECKED HISTORY WITH NONE FOUND FOR 25 DAYS. RAN A COMPLETE AUTO THROTTLE CHECK IAW MM 22-30-00-5 AND ALL SYS TEST NORMAL. A/T SYS IS GOOD TO GO. ACFT IS STILL CAT-2 DUE AUTO BRAKING.