What was found
FS 1270 L CREASE BEAM CORRODED. REMOVED CORROSION IAW SRM 51-10-02. ORIG MATERIAL 0.071 MAT. LOSS 0.010 FOUND TO BE OUT OF LIMITS IAW SRM 53-60-13, FIG 101 DETAIL III . REMOVED CREASE BEAM STA 1180-1285, LBL 68 IAW SRM 51-40-02. FAB CREASE BEAM IAW SRM 53-60-13. LOCATED, DRILLED, AND TRIMMED IAW SRM 51-40-05. TREATED AND PRIMED IAW SRM 51-20-01. INSTALLED CREASE BEAM IAW SRM 51-40-02.