As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MCD FLOOR BOARD SUPPORT CREASE IS CORRODED APPROX BETWEEN STA 1260-1270 AT RBL 65. REMOVED CORROSION IAW 51-10-02 MAT THICKNESS 0.080. AFTER REWORK 0.040 FOUND TO BE OUT OF LIMITS IAW SRM 53-60-13 FIG 101. VARIFIED MATERIAL AS BAC 1515-5537075T6 IAW SRM 53-60-13. LOCATED AND DRILLED IAW SRM 51-60-05. TREATED AND PRIMED IAW SRM 51-20-01. PAINTED WHITE IAW SEM 51-21-04. INSTALLED NEW CREASE BEAM IAW SRM 51-40-02, MAJOR REPAIR.