What was found
C-2 DOOR CUT OUT FWD FRAME BS 950E, INNER CHORD ANGLE IS CORRODED ON UPPER FLANGE LWR SURFACE BTWN STR 27R-26R. REMOVED DAMAGED AREA, FABRICATED NEW ANGLE REPAIR, FILLER, AND INTERCOSTAL; INSTALLED REPAIR PARTS AT BS 950E INNER CHORD ANGLE BETWEEN STR 27R - STR 26R IAW SRM 51-10-6, SRM 53-10-1 FIG 1 AND EA 7-5310-135513.