What was found
SURFACE CORROSION, AFT PIT AT BS 1030, 2 EACH PLACES ON FRAME, ABOVE STR 27R. REMOVED CORROSION FROM BS 1030 FRAME ABOVE STR 27R, ORIGINAL THICKNESS .063", MATERIAL LOSS .002", MATERIAL REMAINING .061", FOUND MATERIAL LOSS TO BE WITHIN LIMITS, TREATED AND PRIMED AREA IAW SRM 51-10-6, SRM 53-10-1, FIG 1, SRM 51-10-2.