What was found
SURFACE CORROSION, AFT PIT AT BS 1010 FRAME, 2 EACH PLACES ABOVE STR 27R. CUT-OUT DAMAGED AREA FABRICATED FRAME REPAIR ANGLE AND INSTALLED REPAIR ANGLE AT BS 1010 ABOVE 27R IAW SRM 51-40-3, FIG 1, SRM 51-10-6, SRM 51-30-2, SRM 51-40-2, AND SRM 53-10-1, FIG 1.