What was found
FWD PIT BS 710-720A 10 INCHES STR 26R CORRODED. CUT-OUT DAMAGED AREA, FABRICATED STRINGER REPAIR IN 2 SECTIONS, ONE FROM BS 700, 10 TO BS 720, 10 STR 26R, 2 FROM BS 720, 10 TO BS 720A, 8 STR 26R, FABRICATED 2 STRINGER SPLICES REPAIR (1), INSTALLED STRINGER REPAIR IAW SRM 53-10-3 FIG 1 AND 51-30-2.