What was found
FRAME AT STA 1280 RT, STR 14-10 HAS GOUGES. REPLACED FRAME SEGMENT FROM STR 7R TO 14R IAW SRM 51-40-05. FRAME SEGMENT FABRICATED ON MAE TR T/9/812786, CHANNEL 1 FABRICATED ON MAE TR T9/812787, CHANNEL 2 FABRICATED ON MAE TR T9/812788. ORIG MAT'L .071 AFTER .046. DAMAGE MEASUREMENTS .025"D X .200"W. MAJOR REPAIR, CATEGORY 'A'.