What was found
DURING TAKEOFF ROLL,HAD ECAM WARNING FOR BLUE LO PRESS HYD SYS. ABORTED TAKEOFF ABOUT 80 KNOTS WITH NO PROBLEMS. DURING AFTER LANDING CHECKLIST NOTICED BLUE HYD SYS PRESSURE FLUCTUATED DOWN TO AS LOW AS 1950 PSI WHILE MOVING FLIGHT CONTROLS WITH NO LOADS REQUIRED OF HYD SYS,THE BLUE SYS IS OK PRESSURE. FOUND BLUE SYS HYD PRESSURE READING 300 PSI. FOUND BLUE SYS HYD PRESSURE READING 300 PSI. R&R BLUE ACCU PRESSURE IAW MM 29-11-56-4. FILL PRESSURE IAW MM 12-14-29. NEED THE FINAL TESTS. FACT 18DEC09 13:37 ACCOMPLISHED TESTS, ACCU CHKD OK. RAN ENG IAW JRH, ALL CHKD OK. ACFT OK TO CONTINUE.