What was found
UPPER CABIN INBD LT CREASE BEAM FS 1370 TO 1640 HAS NUMEROUS AREAS OF CORROSION. BLENDED AND FOUND TO BE OUT OF LIMITS, IAW SRM 53-60-13, FIG 101, PG 105. REMOVED CREASE BEAM, IAW SRM 51-40-02. FABED NEW CREASE BEAM IAW SRM 51-10-02, 53-60-13. INSTALLED CREASE BEAM STA 1370-1640, LBL 65, PER SRM 51-40-02. MAJOR REPAIR.