What was found
FWD CARGO AREA, BS 640, STR 28L, CRACKED FRAME. CUT-OUT DAMAGE IN B640 FRAME AT STR. 28L, 1" X 1 1/4" IAW SRM REV 102, 51-10-1. FABRICATED REPAIR DOUBLER IAW SRM 51-40-3 FIG 1 AND 53-10-2 FIG 3. HEAT TREATED REPAIR DOUBLER TO -T6 CONDITION IAW FAS ENGINEERING REPORT 2-37153-801 REV A. INSTALLED DOUBLER ON FRAME IAW SRM 51-30-2 AND 51-40-3.