What was found
FWD CARGO AREA, BS 620, STR 28R, CRACKED FRAME. CUT OUT DAMAGE IN FWD PIT ON STA 620 FRAME AT STR 28R, IAW SRM 51-10-1. FABRICATED REPAIR DOUBLER IAW SRM 51-40-3, FIG 1 AND 53-10-2 FIG 3. HEAT TREATED REPAIR DOUBLER TO T6 CONDITION IAW FAS ENG REPORT NR 2-37153-801 REV A. INSTALLED REPAIR DOUBLER ON BS 620 FRAME AT STR 28R IAW SRM 51-30-2, REV 102.