What was found
AFT WTB FAIRING EDGE SEALENT AREA APPROX FS 1280 TO 1300, BTW S-27L TO S-27R SKIN HAS SCRATCH DAMAGE AREA GREATER THAN 10" IN LENGTH AND IS WITHIN THE "20X" DAMAGE AREA OF FASTENER. AREA IS OUT OF LIMITS IAW SRM 53-00-01, FIG. 101, DETAIL II. AFTER FURTHER EVALUATION, ABOVE NOTED AREA WAS DETERMINED TO BE WITHIN LIMITS.