What was found
LWR FUSELAGE BS 399 BTW STRS 21 AND 22R SKIN DENTED. INSP FINDINGS MEASURED DENT Y=.012, A=.905 A/Y = 75.4. DENT FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01, FIG 101, DETAIL III. DENT LOCATED DIRECTLY UNDER FRAME LWR TEE CHORD. UPON FURTHER INVESTIGATION DETERMINED DAMAGED AREA TO BE A PREVIOUS BLENDED AREA , CHECKED LIMITS IAW SRM 53-00-01, FIG 101, DETAIL II. FOUND TO BE WITHIN LIMITS. ORIGINAL MATERIAL THICKNESS .125, BLEND DEPTH .007, THICKNESS AFTER REWORK .118. MINOR REPAIR.