What was found
DENT IN ACFT SKIN APROX STA 1345 BETWEEN STR 25R AND 26R. CHECKED LIMITS ON DENT STA 1345 STR 25R-26R ORIG .070, DEPTH OF DAMAGE .020. FOUND OUT OF LIMITS IAW SRM 53-00-01 DET 3 FIG 101, DENT 0.5 X 1.0, REMOVED DAMAGE SKIN STA 1345 IAW 53-00-01 HFEC DENT CUT OUT IAW NTM 51-00-19 PT 6, NO CRACKS NOTED , FABED REPAIR PARTS DOUBLER AND FILLER IAW SRM 53-00-01 LOCATED AND DRILLED, TREATED AND PRIMED AND INSTALLED REPAIR PARTS IAW SRM 51-40-02, THIS IS A CATEGORY "B" REPAIR , INSP THRESHOLD EVERY 24,000 FLIGHT CYCLES IAW SRM 53-00-01 TABLE 3.