What was found
MCD FLOOR SUPPORT WEB SURFACE IS CORRODED BETWEEN STA 700 TO STA 720 AT LBL 64. R & R GUTTER SUPPORT. CHECKED LIMITS, FOUND OUT OF LIMITS IAW SRM 53-00-51, PG. 103, FIG. 101, DETAIL II. MINOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCD FLOOR SUPPORT WEB SURFACE IS CORRODED BETWEEN STA 700 TO STA 720 AT LBL 64. R & R GUTTER SUPPORT. CHECKED LIMITS, FOUND OUT OF LIMITS IAW SRM 53-00-51, PG. 103, FIG. 101, DETAIL II. MINOR REPAIR.