What was found
STA 1401, 1" BELOW S-25L. FUSELAGE SKIN IS DENTED. MEASURED DENT AT STA 1401 S-25L, A=1.0, Y=.050 . A/Y= 20, FOUND OUT OF LIMITS IAW SRM 53-00-01 FIG 101 DETAIL III. REMOVED SHEAR TIE BETWEEN S-25L TO S-26L. CUT OUT DAMAGED SKIN 3"X4" IAW SRM 53-00-01 FIG 201 REPAIR 2. FABRICATED DOUBLER AND FILLER IAW SRM 53-00-01 FIG 201 REPAIR 2. LOCATED AND DRILLED HOLES IAW SRM 51-40-05. TREATED AND PRIMED IAW SRM 51-20-01. ENLARGED CUT OUT BY .040 IAW SRM 53- 00-01 FIG 201 REPAIR 2. INSTALLED ALL PARTS IAW SRM 51-40-02. CLASSIFIED CATEGORY "B" MAJOR REPAIR WITH HFEC INSP AT 37,500 FC WITH INTERVALS AT 6000 FC IAW TABLE V OF SRM 53-00-01 FIG 201 REPAIR 2.