What was found
CORROSION AROUND FASTENERS AT AFT PIT STA 1030 TO STA 1070 STRINGER 27L. REMOVED CORROSION AND FOUND OUT OF LIMITS. CUTOUT STRINGER DAMAGE, FABRICATED FILLER USING BAC1498-145 7075T-6 PO NR 2905741 DIMS 19" AND SPLICES USING BAC1498-131 7075T-6 PO NR 2912086 DIMS 14" AND INSTALLED IAW SRM 51-10-6, 53-10-1, 53-10-6, AND 51-30-2.