What was found
RT WING INBD UPPER FLAP L/E STRUCTURE HAS CHAFINGS. REMOVED CHAFE FROM RT WING INBD FLAP IAW SRM 57-53-01, FIG 101 DETAIL VI. FOUND TO BE OUT OF LIMITS. ORIG MATERIAL 0.055 AFTER REWORK 0.049. CUT OUT DAMAGE AREA IAW SRM 57-53-01 FIG 201 REPAIR 2. REMOVED PANEL IAW SRM 51-40-02. FABRICATED 2EA DOUBLERS AND REPAIR PLATE. FABRICATED STRAPS IAW SRM 57-53-01 FIG 201. LOCATED AND DRILLED HOLES IAW SRM 51-40-05. TREATED AND PRIMED IAW SRM 51-20-01. INSTALLED ALL REPAIR PARTS IAW SRM 51-40-02. REINSTALLED PANEL IAW SRM 51-40-02. CLASSIFIED CATEGORY "A" MAJOR REPAIR