Service difficulty report · Line · Doug MD11F

Difficulty date
January 20, 2010
Submitted
January 20, 2010
Operation
Air carrier
Aircraft
N608FE
Make and model
Doug MD11F
Aircraft serial
48548
Aircraft time
58,836 hours, 13,392 cycles
Part
Line
Condition
Ruptured
Location
Hyd System
Stage of operation
CL
How discovered
O
Nature of condition
K, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING SLAT RETRACT GOT LEVE 1 "SLAT DISAG" WITH ROLLING MOTION TO THE RT. COMPLIED WITH RED TABS AND RETURNED TO DTW DECLARING EMERGENCY LANDING. ACFT TOWED OFF RUNWAY. FOUND RT SLAT ACT INBD LINE BROKEN. INSTALLED PERMANANT REPAIR TO SLAT HYD LINE IAW MM 20-10-01-2. REPAIRED LINE INSTALLED, AND LEAK CHECK NORMAL, OPS CHECK NORMAL IAW 27-82-00-0. REMOVED AND REPLACED HYD SYS NR1 MANIFOLD FILTERS. REPLACED NR 1 ENG HYD PUMP MANIFOLD FILTERS. REPLACED NR 1 ENG RT AND LT EDPS, DUE TO HYD SYS FULLY DEPLEATED. ALL OPS AND LEAK CHECK GOOD. OK FOR SERVICE.

More about the Doug MD-11F