What was found
L-1 DOOR UPPER AND LOWER HINGE CUTOUT DOUBLERS HAVE COUNTERSUNK FASTENERS INSTALLED. REMOVED DOUBLERS, FABRICATED 2 NEW DOUBLERS, CADMIUM PLATED DOUBLERS IAW SOPM 20-40-01 AND INSTALLED IAW EO 7-5330-7-2345 PT 2 AND SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L-1 DOOR UPPER AND LOWER HINGE CUTOUT DOUBLERS HAVE COUNTERSUNK FASTENERS INSTALLED. REMOVED DOUBLERS, FABRICATED 2 NEW DOUBLERS, CADMIUM PLATED DOUBLERS IAW SOPM 20-40-01 AND INSTALLED IAW EO 7-5330-7-2345 PT 2 AND SRM 51-30-2.