What was found
AVIONICS COMPARTMENT FLOOR SUPPORT WEB HAS 4 EA ELONGATED HOLES FROM FRAME 7 TO FRAME 10; RBL 40 TO RBL 47. REMOVED WEB. LOCATED AND DRILLED NEW WEB. INSTALLED NEW WEB IAW SRM 51-72-10, PGS 1-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AVIONICS COMPARTMENT FLOOR SUPPORT WEB HAS 4 EA ELONGATED HOLES FROM FRAME 7 TO FRAME 10; RBL 40 TO RBL 47. REMOVED WEB. LOCATED AND DRILLED NEW WEB. INSTALLED NEW WEB IAW SRM 51-72-10, PGS 1-3.