What was found
MAIN CARGO DOOR AFT EDGE AT STR 10 LT IS BENT OUT. TRIMMED OUT DAMAGED AREA, HFEC INSPECTED CUTOUT WITH NO DEFECTS NOTED IAW NDTM 51-00-00, HFEC INSPECTED HOLES WITH NO DEFECTS NOTED NDTM 51-00-00, FABRICATED DOUBLER, TRIPLER, FILLER AND INSTALLED IAW EA 7-5320-135522.