What was found
FLOORBEAM (UNDERSIDE) AT STA 345 LBL 64, HAS CORROSION. REMOVED CORROSION ON FLOORBEAM STA 345, LBL 64. ORIG MAT .125, MAT. LOSS .040, REMAINING MAT .085 OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL VI. REMOVED AND INSTALLED FLOORBEAM REPAIR CHORD AT STA 345, LBL 54 TO LBL 70 PN BAC 1505-100880 IAW SRM 51-40-02, FIG I AND 51-10-02, 53-00-51. MAJOR REPAIR.