What was found
AFT CARGO LT FRAME AT STA 1560 LOWER SIDEWALL SUPPORT FOUND CRACKED AT FASTENER HOLE AREA. CRACKED LT SIDEWALL SUPPORT AT STA 1560 R & R IAW SRM 51-40-02 REV 99. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRTIERIA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO LT FRAME AT STA 1560 LOWER SIDEWALL SUPPORT FOUND CRACKED AT FASTENER HOLE AREA. CRACKED LT SIDEWALL SUPPORT AT STA 1560 R & R IAW SRM 51-40-02 REV 99. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRTIERIA.