What was found
FWD PIT - CORROSION ON SHEAR TIE AT BS 540, BETWEEN STRINGERS 28L AND 28R. REMOVED CORROSION IAW SRM, REV 102, 51-10-6. UT INSPECTED AREA IAW NDTM 51-00-00, FIGURE 3, PART 4. ORIGINAL THICKNESS OF .046", MATERIAL LOSS OF .001", MATERIAL REMAINING .045". AREA FOUND TO BE WITHIN LIMITS IAW SRM 53-10-1.