What was found
CORROSION FLOORBEAM MAIN CABIN BS 1110, RBL12. CUTOUT DAMAGED FLOORBEAM DIM: 1.9" X 2" IAW SRM 53-10-8, FIG 3 FABRICATED FLOORBEAM REPAIR, SUPPORT ANGLE, AND STRAP IAW SRM 53-10-3 FIG 3. TREATED AND PRIMED REPAIR PARTS IAW SRM 51-10-2. INSTALLED REPAIR PARTS AT BS 1110 RBL 12 IAW SRM 51-30-2 & SRM 53-10-8, FIG 3.