What was found
MDCC FLOORBEAM AT FR 65 BETWEEN SEATTRACKS 3L AND 4L IS BENT/ DISTORTED APPROX 18 " IN LONG X .08 DEFLECTION. REPAIRED FLOORBEAM AT FR 65 BETWEEN 3L AND 4L USING SPLICING METHOD IAW SRM 53-10-15, CONFIG 2, PG 27, FIG 3, SHEET 2 COMPLIED WITH REQUIRED OPS TEST REFERRED TO ON JPF ATTACHED FOR INDIVIDUAL SIGNOFFS.