What was found
STA 1600 LBL 19.25 STR 3L FRAME HAS A DOUBLE DRILLED HOLE R & R FRAME SECTION STA 1600 STR 5L-5R IAW SRM 51-40-02 AND 53-00-07 PG 203, FIG 201 DET II. FABRICATED NEW FRAME SECTION W/TRAVELER T10/819092, FABBED CHANNELS NR 1 &NR 2 W/ TRAVELER'S T10/819080, T10/819091, T10/820272. CLASSIFIED AS MAJOR REPAIR.