What was found
FUSELAGE FRAME BS 980 ABOVE S17R OUTER CHORD HAS CORROSION OUTER CHORD FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07, FIG. 101, DET. II, PG. 101-103, ORIGINAL MAT. THICKNESS IS .090', REM. THICKNESS IS .073", MAT. REM. .017'. REMOVED AND REPLACED FAILSAFE IAW SRM 51-40-02, FAB ON TRAV T10/821853