What was found
FLOORBEAM HAS CORROSION AT STA 345 LBL 12 TO 17. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51. FIG 101, DET III. FABRICATED UPPER T-CHORD MAT BAC 1505-100880, REPAIR ANGLES MAE TRAV NR T10/824058, AND REPAIR STRAPS MAE TRAV NR T10/824060. INSTALLED UPPER T-CHORD , REPAIR ANGLES, AND STRAPS STA 345, RBL 70- LBL 52, IAW SRM 53-00-51, FIG 201, CATEGORY "A", REPAIR 3. MAJOR REPAIR.