What was found
RT INBD FOREFLAP CARRIAGE ATTACH FITTING AREA AT STA 224, SKIN CRACKED FWD OF ATTACH FITTING. CUT OUT DAMAGED AREA, DIMENSIONS .750" X .218" IAW SRM, REV 102, 57-50-4, FIG. 1. FABRICATED FILLER USING 2024 T-3, PO NR 9002222, DIMENSIONS .050" X .750" X .218" AND DOUBLER USING 2024 T-3, PO NR. 9009353, DIMENSIONS .063" X 5" X 4.375" IAW SRM 57-50-4 FIG 1 AND 57-50-2 FIG 3. TREATED AND PRIMED DOUBLER, FILLER, AND REPAIR AREA IAW SRM 51-10-2. INSTALLED REPAIR DOUBLER AND FILLER IAW SRM 51-30-2 AND 57-50-4 FIG 1.