What was found
WIRE BUNDLE STAND OFF BROKEN AND FRAME DAMAGED, STA 460, STR 8R. REMOVED DAMAGED STAND OFF IAW SRM 51-30-2. DRILLED OUT DAMAGE AT FRAME UP TO .125 DIA IAW SRM 53-10-1, FIG 1 AND INSTALLED .1250" SOLID FASTENER AT FRAME IAW SRM 51-30-2. INSTALLED NEW STAND OFF IAW SRM 51-30-2.