As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME DAMAGED BY TOO LONG HARDWARE INSTALLED IN WIRE BUNDLE STAND OFF CLAMP, STA 500, STR 8R. REMOVED STAND OFF IAW SRM 51-30-2. DRILLED OUT DAMAGED AREA .125 DIA IAW SRM 53-10-1, FIG 1 INSTALLED .1250" SOLID FASTENER IAW SRM 53-10-1 FIG 1 & 51-30-2. INSTALLED NEW STAND OFF IAW SRM 51-30-2.