What was found
FRAME 58-62; LBL 56; STRINGER CORRODED. REMOVED STRINGER AT LBL 56 FROM FRAME 58 TO 62 & STR SPLICE AT FRAME 58 IAW SRM 53-10-14. RECEIVED NEW STRINGER, LOCATED AND DRILLED NEW STR SECTION IAW SRM 51-40-44 & SRM 53-10-14. FABBED SPLICE IAW SRM 53-10-14; FIG 210A; PGS 204A/ 240B. REMOVED CORROSION AT STRINGER LBL 56 IAW SRM 51-74-10 AND FOUND TO BE OUT OF LIMITS. ORIGINAL THICKNESS 0.172", MATERIAL REMOVED 0.044", MATERIAL REMAINING 0.128" IAW SRM 53-10-10; TABLE 102; PG 175. ALODINED STR AND SPLICE IAW SRM 51-21-10, 1. PRIMED STRINGER AND SPLICE IAW SRM 51-23-10; PG 2. PAINTED SPLICE IAW SRM 51-25-10. INSTALLED NEW STRINGER AND SPLICE IAW SRM 53-10-14; FIG 201A; PGS 204A/ 204B.