What was found
NR 1 CARGO DOORWAY FRAME, BS 620, STR 25R, WEB CRACKED, ORIGINATING FROM SEAL RETAINER FASTENER HOLE. REMOVED WEB AT BS 620 FRAME FROM STRINGER 16R TO 28R IAW SRM, REV 102, 51-30-2. FABRICATED NEW WEB USING 7075-T6, .071" X 24" X 139.5" IAW MFG DWG NR 65-56101 REV F. INSTALLED WEB IAW SRM, REV 102, 51-30-2.