What was found
UPON ACCOMPLISHMENT OF SNRM N00646, CRACK INDICATION FOUND DURING HFEC OPEN HOLE INSP ON 1 EACH FASTENER HOLE AT STA 5-53 LONGERON 1L. CRACK AT 1 EACH FASTENER HOLE STA 5-53 LONGERON 1L REPAIRED IAW SRM 53-00-05 FIG 202. REPAIR 1 REVISION 43. INTERCOSTAL R & R IAW SRM 51-31-01, REV 43. NEW INTERCOSTAL FABRICATED IAW DWG AFA 3121 SHEET 2, REV AV. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100 REV 109.