As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FASTENERS WITH IMPROPER SPACING FWD PIT STA 640 STR 27L. CUT OUT DAMAGE AREA TO SKIN STA 640 STR 27L. FABRICATED STRUCTURAL FILLER, DOUBLER AND TRIPLER IAW SRM 53-30-3 FIG 1B CUT OUT DAMAGE SHEAR TIE IAW SRM 53-10-4, FIG 15. FABRICATED SHEAR TIE IAW SRM 53-10-4 FIG 15. INSTALLED SKIN REPAIR PARTS FILLER, DOUBLER AND TRIPLER IAW SRM 53-30-3, FIG 1B AND INSTALLED SHEAR TIE IAW SRM 51-30-2.