What was found
FASTENERS WITH IMPROPER SPACING FWD PIT STA 620 STR 27L. CUT OUT DAMAGED AREAS, FABRICATED REPAIR DOUBLER USING 2024T-3 .080 DIMS 89" X 29.5", TRIPLER USING 2024T-3, .125 DIMS 87" X 27.5", 2 STRUCTURAL FILLERS USING 2024T-3 .125 DIMS 90" X 25.5" AND 2024T-3 .063 DIMS 19" X 7.75", CUT OUT FILLERS USING USING 2024T-3 .125 DIMS 6.5" X 4.3750" AND 1.6250" X 5.6250", SHEAR TIES USING BAC1505-1001557075T6 DIMS 6", SHEAR TIES USING 7075-O .063 DIMS 7" X 3", HEAT TREATED PARTS TO T6 CONDITION IAW ENG REPORT 2-37153-801, REV A AND INSTALLED ALL PARTS IAW P-F SRM 53-30-3, SRM 53-10-4 AND SRM 51-30-2.