What was found
FWD CARGO AREA, BS 600, STR 21L, STRINGER HAS DOUBLE DRILLED HOLE. CUT OUT DAMAGED STRINGER DIMS 13" X 3", FABRICATED FILLER USING BAC1498-140 7075T-6 PO NR 2910023 DIMS 13" X 3", FABRICATED 2 SPLICES USING BAC1498-132 7075T-6 PO NR 20017112, DIMS 12" X 3" AND 12" X 3" AND INSTALLED IAW SRM 53-10-3, 51-10-2 AND 51-30-02.