What was found
FASTENERS WITH IMPROPER SPACING FWD PIT STA 540, STR 27L CUT OUT DAMAGED AREA THRU SKIN MCD STA 540 STR 27L IAW SRM 53-30-3, FIG 1B FABRICATED STRUCTURAL FILLER, DOUBLER AND TRIPLER IAW SRM 53-30-3 FIG 1B CUT OUT DAMAGED SHEAR TIE IAW SRM 53-10-4, FIG 15 FABRICATED SHEAR TIE IAW SRM 53-10-4 FIG 15, INSTALLED REPAIR SKIN PARTS IAW SRM 51-30-2 REV 102, INSTALLED SHEAR TIE REPAIR IAW SRM 53-10-4 FIG 15