What was found
FWD PIT STA 564 STRINGER 26L CORRODED. CUT OUT DAMAGED STRINGER DIMS 19" X 3" IAW SRM 53-10-3, FABRICATED FILLER USING BAC1498-140 7075T-6 PO 2910023 DIMS 19" X 3" IAW SRM 53-10-3. FABRICATED 2 EACH SPLICES USING BAC1498-132 7075T-6 PO 29067380 DIMS 14" X 3" AND 13" X 3" IAW SRM 53-10-3 AND INSTALLED IAW SRM 51-30-2.