What was found
FWD PIT - CORROSION ON SHEAR TIE AT BS 585, BETWEEN STRINGERS 27R AND 26R - MARKED. REMOVED FRAME TO BS 585 BETWEEN STR 27R AND 26R IAW SRM 51-30-2 FABRICATED NEW FRAME MATERIAL USED 7075 - 0 .063" PO NR 9009527 DIM 10" X 6.5" IAW SRM 51-20-1, FIG 7 AND 51-10-3 HEAT TREATED PART FROM 7075-0 TO 7075-T6 IAW ENGINEERING REPORT NR 2-37153-801, REV A. INSTALLED NEW FRAME IAW SRM 51-30-2 INSTALLED FLOOR SUPPORT IAW SRM 51-30-2.