What was found
PREVIOUS REPAIR LOCATED AT STA 1223 STR 23R REQUIRES EVALUATION IAW EO 7-5100-7-5005 PH. REPAIR HAS BLIND FASTENERS INSTALLED. REMOVED BLIND FASTENERS AND INSTALLED SOLID FASTENERS IAW SRM 53-30-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PREVIOUS REPAIR LOCATED AT STA 1223 STR 23R REQUIRES EVALUATION IAW EO 7-5100-7-5005 PH. REPAIR HAS BLIND FASTENERS INSTALLED. REMOVED BLIND FASTENERS AND INSTALLED SOLID FASTENERS IAW SRM 53-30-3.