What was found
CORROSION LOWER SURFACE OF UPPER TEE ON FLOORBEAM STA 1110, BETWEEN RBL 45 AND RBL 65. AREA FOUND TO BE OUT OF LIMITS IAW SRM 53-10-1 FIG 4. CUT-OUT DAMAGED AREA OF UPPER TEE DIM: 6" X 2" AND FABRICATED UPPER TEE FROM BAC1505-100617 7075T6, PO NR 29094137 DIM: 23" ANGLE SUPPORT FROM BAC14902785 PO NR 29118113 DIM: 23" X .8750" X 1.8750, ANGLE SUPPORT FROM 7075T6 .090 PO NR 9008486 DIM: 18.3750" X .9375" X 1.3750". REINFORCE STRAP FROM BAC1512-3353 PO NR 9003263 DIM: 22" LONG REINFORCED STRAP FROM BAC 1512-3396. PO NR 9007927 DIM: 18.3750" LONG AND INSTALLED REPAIR PARTS IAW SRM 53-10-8, FIG 1.